Range (measurement & indication) |
0 - 30 ppm, Trend up to 50ppm |
Range (IMO specification) |
0 - 15 ppm (according IMO regulations) |
Accuracy |
better than IMO MEPC.107(49) |
Electrical power supply |
24V - 240V, AC or DC, automatic voltage adjustment |
Electrical power consumption |
< 15 VA |
Sample |
Oily water from separator outlet, 0,1 - 4 l/min |
Sample temperature range |
+1°C to +65°C |
Sample connections |
R 1/4" Female |
Alarm 1 & 2 Set Points |
1 - 15ppm (independently adjustable) |
Alarm 1 operating delay for annunciation |
1 - 540 sec |
Alarm 2 operating delay for control |
1 - 10 sec |
Alarm contacts |
2 independently adjustable switchover contacts |
Alarm contact operation mode |
De-energized in Alarm State |
Alarm contact ratings |
3A, 240V each |
Alarm output |
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150? |
Display |
Green Graphic Display |
Ambient temperature |
+1°C to +55°C |
Class of protection |
IP 65 |
Dimensions |
360 x 240 x 100 mm (WxHxD) |
Weight |
7,3 kgs |